ShipsLog™ DataLogger for Vapour Shippers from Planer
Features
- Temperature alarms settable by user
- High and low temperature alarms
- Records of sample temperature
- Soft or hard copy report options
- Alarms trip points that can be set
- A visual LED warning
- Log intervals that can be set for each shipment
- Alarm delays which are programmable
- User programmable
- Print in graphical or tabular form
- Battery life of approximately 3 years
- Archiving facility for logged data
- Specific segments can be printed
- View current temperature via software
- Hard disk or external drive
- Probe accuracy of ± 1.3° C at -200° C
- Software settings password protected
- Analysis of the data can be made by the sender, the receiver or both
- Temporary removal of cork and cover need not initiate alarm status
- Logging intervals can be set from 30 seconds to 99 minutes
- Store up to 8,192 entry logs
- Available with a "flying lead" to record the temperature closer to sample area
The Planer ShipsLog™ is a datalogger for vapour shippers which will keep an accurate and downloadable temperature history of samples over the duration of the transit.
The ShipsLog™ is an on-line monitoring system of temperature history for samples in liquid Nitrogen Vapour Shippers. It provides traceability for the temperature of the samples and can give alarms at setpoints during the transit period.
The ShipsLog™ monitor is fitted in the top of the dry shipper's cover. The temperature probe (PLPT100) extrudes through the 'cork', monitoring the temperature at the warmest part of the vapour shipper.
The temperature sensor is fitted to a plate which prevents physical damage to the sensor and also ensures that the temperature recorded is higher than the temperature in the vicinity of the sample.
The ShipsLog™ can also be supplied with a flying lead should it be required to record the temperature within the sample area - this unit is not fitted with, or supplied with a cork and cover.
Samples may be transported in the knowledge that on arrival at destination the recipient can quickly check via the LED display whether the temperature range has deviated from the pre set profile.
The full temperature history can be downloaded if desired to confirm the exact temperature pattern throughout the journey. The logger is user programmable via PC software.
The logging process can be started either via the PC software or via a magnetic swipe key - which can be shipped separately from the vapour shipper. Analysis of the data can be made by the sender, the receiver or both.
Key Features
- Record of sample temperature
- Soft or hard copy
- Alarms trip points can be set
- Visual LED warning
- User programmable
Software
- User programmable
- Archiving facility for logged data
- Hard disk or external drive
- Print in graphical or tabular form
- Specific segments can be printed
Temperature Check
- Log intervals can be set for each shipment
- Temperature Alarms settable by user
- Logging intervals can be set from 30 seconds to 99 minutes
- Store up to 8,192 entry logs
Alarms
- High and low temperature alarms
- Alarm delays programmable
- Temporary removal of cork and cover need not initiate alarm status
Precision Accuracy
- Probe accuracy of ± 1.3° C at -200° C
- Battery life of approximately 3 years
- View current temperature via software
- Software settings password protected
A data logger for vapour shippers in transit - the Planer ShipsLog™
It keeps an accurate and downloadable temperature history of samples over the duration of a transit.
The unit gives a temperature history for samples in vapour shippers - liquid nitrogen charged 'Dry Shippers' - and provides traceability for the temperature of the samples; it can be set to give alarms at set points during the transit period.
The logger is programmable via PC software and the process can be started either via the PC software or via a magnetic swipe key. The key can be sent separately from the vapour shipper.
Samples may be transported in the knowledge that on arrival at destination the recipient can quickly check via the LED display, whether the temperature range has deviated form the pre-set profile.
The ShipsLog is widely used when valuable cryo-frozen samples, pharmaceutical, medical or zoological, are transported by air, road or sea.
Available Models
Product Code
|
Description
|
PLGDSHIPSLOG-FL
|
ShipsLog™ Datalogger with 1 Temperature Probe, Each
|
PLGDSHIPSLOG-FL-720
|
ShipsLog™ Datalogger with 1 x 720 mm Long Fixed Probe, Each
|
PLGDSHIPSLOG-CS
|
ShipsLog™ Datalogger for Cryoshipper Vapour Shipper, Each
|
PLGDSHIPSLOG-SC4/3V
|
ShipsLog™ Datalogger for PLSC4/3V Vapour Shipper, Each
|
PLGDSHIPSLOG-SC4/2V
|
ShipsLog™ Datalogger for PLSC4/2V Vapour Shipper, Each
|
Accessories
Product Code
|
Description
|
PLGDSHIPSLOG-PRT-610MM
|
Temperature Probe for ShipsLog, Each
|
PLAC013808
|
Serial Cable to Connect ShipsLog to PC, Each
|
Specifications
|
PLSHIPSLOG
ShipsLog™ Datalogger for Vapour Shippers
|
Measurement
|
Range
|
--200° to 0° C
|
PC Programme
|
Display units user selectable - ° C, ° F, or K
|
Probe Type
|
Platinum Resistance, Pt 100, Class B
|
Accuracy
|
± 1.5° C at 0° C, rising to ±2.5° C at 0° C, rising to ±2.5° C at -200° C, including uncertainty due to measurement resolution and probe errors
|
Calibration
|
Traceable to NAMAS standards; semi-automatic user calibration possible using optical PC calibration pack; calibration certificate printed automatically
|
Data Logging
|
Number of Points
|
8,192
|
Logging Interval
|
30 seconds to 99 minutes in 30 second increments
|
Logging Resolution
|
0.1° C
|
Maximum Number of Logs
|
8,192 (Limited to number of points)
|
Alarm Generation
|
High Alarm Level
|
-200° C to 0° C in 1.0° C steps
|
Low Alarm Level
|
-200° C to 0° C in 1.0° C steps
|
Alarm Delay Period
|
0 to 120 logging intervals
|
Control & Indication
|
Manual Control
|
Magnetic non contact Start / Stop Switch using supplied fob
|
Communication
|
RS232 Serial communications to proprietary PC program
|
Programming
|
Using propriety PC program
|
Indicator
|
Three x LED Indicators: Yellow=Normal, Orange=Warning
|
Battery
|
Type
|
Lithium Thionyl Chloride, internally fitted, factory replaceable
|
Life
|
Approximately 3 years in normal operation; battery life remaining is indicated via PC programme
|
PC Software Requirements
|
PC to be minimum Windows '95, '98, or NT
|
Warranty
|
1 Year
|
|
|
|
|
*Please select the quantity for each item you wish to order and click the 'Add To Cart' button below. |
|